Previously PBI Height Safety

Kingspan Safepro2 Surface Mounted Cable Static Lifeline

A high-strength anchor and cable system with energy-absorbing posts that limit the fall arrest load to less than 6kN.
PBI_Logo_Asset_45_x_75_px-1

Specs & Details

  • Key features
  • Technical Information

Kingspan's SafePro2 Surface Mounted Cable Static Lifeline has been designed for use across all types of Kingspan Insulated Roof Panels.

HOW IT IS USED

Kingspan SafePro2 Surface Mounted Cable Static Line is designed to be installed on the building roof. The system is typically used where the operative is required to move laterally over a significant distance whilst staying connected. The system provides fall protection for operatives doing a range of activities including roof wash downs, installing & maintaining HVAC air conditioning units, general maintenance, or gutter cleaning. The fall arrest system is designed to support and hold a person in the event of a fall.

HOW IT WORKS

In the event of a fall, the anchor breaks open, deploying the unique and patented Force Management Technology absorbing system which reduces the forces generated on the roof structure to less than 610kg. (6kN). In the unlikely event that the anchor is deployed, it is possible to remove the module and replace it with a new one. SafePro2 Cable requires less training and experience compared to single anchor points making it one of the safest systems to use. 

PERFORMANCE

SafePro2 Surface Mounted Cable Static Lifeline meets AS/NZS 1891.2:2001 - Industrial fall-arrest systems and devices - Horizontal lifeline and rail systems safety standards, AS/NZS 1891.4:2009 - Industrial fall-arrest systems and devices - Selection, use, and maintenance, designed for and tested on most roof types, EN 795 and OHSA 1926. SafePro2 roof anchors incorporate Force Minimisation Technology, which limits the load transferred to the roof, in a fall arrest event, to let than 6Kn.

 


 

INSTALLATION

Installation must be carried out by a manufacturer-trained technician who is familiar with the parameters of fall arrest systems.

MAINTENANCE

As per AS/NZS 1891.4 SafePro2 cable must be certified every 12 months by a qualified height safety equipment inspector. All of the exposed materials in the system have been specified as naturally corrosion-resistant, or have been coated with sacrificial coatings to prevent oxidization of the base material. It is important to consider that in some environments the system may need to be cleaned to gain the best possible life expectancy from the materials.

WARRANTY

SafePro2 cable system has a product warranty of 10 years from the date of installation. The warranty is invalidated if inspections are not maintained every 12 months by a qualified height safety equipment inspector. 

PBI_Logo_Asset_45_x_75_px-1

Projects

Specific to product

Thermosash Project | Alta Safety

Thermosash Project | Alta Safety

Architect: Create Architects and Engineers

Contractor: Thermosash

Location: Levin, New Zealand


  • Solution

    3M Cable Fall Arrest System

  • Scope Requirements

    Fall Arrest

Te Kura Whakatipu O Kawarau

Te Kura Whakatipu O Kawarau

Architect: Stephenson & Turner Architects

Contractor: Southbase Construction

Location: Queenstown, New Zealand


  • Solution

    3M Roofsafe Surface Mounted Cable Static Line

  • Scope Requirements

    Fall Arrest

Toll New Zealand

Toll New Zealand

Architect: Williams Architects

Contractor: Watts Group

Location: Auckland, New Zealand


  • Solution

    3M RoofSafe Cable

  • Scope Requirements

    Fall Arrest

Manukau Bus & Train Interchange

Manukau Bus & Train Interchange

Architect: Cox Architecture

Contractor: NZ Strong

Location: Auckland, New Zealand


  • Solution

    Kingspan Safepro2 Cable Static Lifeline

  • Scope Requirements

    Fall Arrest

Wanaka Recreational Centre

Wanaka Recreational Centre

Architect: Warren & Mahoney

Contractor: Cook Brothers Construction

Location: Wanaka, New Zealand


  • Solution

    Safepro2 Cable, 3M Fall Arrest Anchors

  • Scope Requirements

    Fall Arrest

Giltrap Group Showroom

Giltrap Group Showroom

Architect: Warren & Mahoney

Contractor: Hawkins

Location: Auckland, New Zealand


  • Solution

    3M Roofsafe Rail, Larkin Needle Frames

  • Scope Requirements

    Abseil & Facade Access & Fall Arrest

Smales Farm Business Park

Smales Farm Business Park

Architect: Jasmax & BVN Architecture

Contractor: Leighs Construction

Location: Auckland, New Zealand


  • Solution

    Altrac Rail, Safepro2 Anchor & Cable

  • Scope Requirements

    Fall Arrest & Abseil

Queen’s Residence

Queen’s Residence

Architect: Leuschke Architects

Contractor: Scarbro Construction

Location: Auckland, New Zealand


  • Solution

    Davits, UniRail, Cable, Anchor Points

  • Scope Requirements

    Fall Arrest & Abseil

Deloitte Christchurch

Deloitte Christchurch

Architect: Jasmax

Contractor: Southbase Construction

Location: Christchurch, New Zealand


  • Solution

    3M RoofSafe Cable & Abseil Anchor Points

  • Scope Requirements

    Fall Arrest & Abseil

Christchurch Transport Exchange

Christchurch Transport Exchange

Architect: Architectus

Contractor: Southbase Construction

Location: Christchurch, NZ


  • Solution

    3M RoofSafe Cable, 3M Fall Arrest Anchors

  • Scope Requirements

    Fall Arrest

idea

Have a project or question?

LET'S CHAT HEIGHT SAFETY - IT IS WHAT WE DO!

Lets Chat

Whether you’re after detailed drawings and a design specification or have a general questions about fall protection and working at height, we would love to hear from you.

For over 21 years our trusted team have been helping keep people and property safe at height. Afterall, making safety an instinctive culture is our vision. 

Looking to upload project details and engage with PBI Height Safety? Tell us about your project and upload drawings here. 