Previously PBI Height Safety

SafetyLink TileLink Anchor Point

The TileLink Anchor is a multi-directional timber or steel truss roof anchor and comprises of one component, making installation much simpler and time effective.

PBI_Logo_Asset_45_x_75_px-1

Specs & Details

  • Key features
  • Technical Information
  • Recertification Requirements

Fall arrest anchor constructed of stainless steel components and designed to be fixed onto the timber truss.

HOW IT IS USED

Anchorage provides a secure connection point for a fall protection system designed to stop a person from injuring themselves where there is a fall from height.

HOW IT WORKS

Safetylink TileLink Anchors patented design absorbs energy. In the event of a fall, the anchors absorb the energy, reducing the risk of injury to the user and damage to the structure. Indication of deployment; energy absorbing regions are expanded, signals the Tile Link should be replaced. 

PERFORMANCE

Conforms to AS/NZS 1891.4:2009 - Industrial fall-arrest systems and devices - Selection, use, and maintenance. All anchors are certified to the requirements of AS/NZS 5532 as a single-person fall arrest anchor point able to sustain a force of 15kN.

 


 

INSTALLATION

All roof anchors are required to be installed by a competent person and recertified annually or more frequently as required or if used in highly corrosive environments. Further details can be obtained from AS/NZS 189.4:2009 or by contacting PBI Height Safety.

MAINTENANCE

As per AS/NZS 1891.4 Safetylink Tilelink Anchors must be certified every 12 months by a qualified hight safety equipment inspector. All of the exposed materials in the system have been specified as naturally corrosion-resistant, or have been coated with sacrificial coatings to prevent oxidization of the base material. It is important to consider that in some environments the system may need to be cleaned to gain the best possible life expectancy from the materials.

WARRANTY

SafetyLink warrants that at the time of shipment, products manufactured by them will be free from defects in material and workmanship. In absence of a modified written warranty, the company agrees to make good any such defects by repairing the same or at the companies option by replacement, for a period of 1 year from the date of shipment. 

 

 

idea

Have a project or question?

LET'S CHAT HEIGHT SAFETY - IT IS WHAT WE DO!

Lets Chat

Whether you’re after detailed drawings and a design specification or have a general questions about fall protection and working at height, we would love to hear from you.

For over 21 years our trusted team have been helping keep people and property safe at height. Afterall, making safety an instinctive culture is our vision. 

Looking to upload project details and engage with PBI Height Safety? Tell us about your project and upload drawings here. 

1